Place a piece of paper on print bed. Nozzle tip must be clean and printer powered off.

Manually lower x-carriage until nozzle tip just touches paper.

Completely loosen PINDA probe

Place PINDA probe squarely upon 0.8 mm thick PINDA height gauge. https://www.thingiverse.com/thing:355564.... If you lack a gauge, a zip tie is usable, but sometimes a bit too thick)

Clamp PINDA in position.

Turn printer on and raise Z to bump against top stops to level x-carriage.

Perform XYZ and Live-Z calibrations after completing extruder install.